  BRENNAN DRY SUMP SCHEMATIC FOR PREFERRED CLOSED SYSTEM
A: Engine
B: Brennan External Belt Driven Scavenge and Pressure Pump
C: #10 or #12 Lines - Scavange and Pressure
D: Brennan Dry Sump Oil Pan
E: Brennan Oil Tank Heater
F: Oil Filter (Or Prefer to remote mount using Fram HP6)
G: #12 or # 16 Lines
H: Oil Cooler or Brennan Heat Exchanger
I: Brennan Screen Filter
J: #12 or #16 Scavenge Lines
K: Brennan Oil Tank Reservoir
L: Overflow and Breather Tank
M: #12 or #16 Vent Line
N: #12 or #16 One Way Valve
NOTE: Line size depends upon whether 4/6/or 8 cylinder - when ordering pump get line size recommendation.

|